Honeywell Sensepoint XCD

Code: SPXCD
  • Flammable (catalytic or infrared), toxic & oxygen versions
  • Plug-in sensor replacement
  • International Approvals

In StockMake An Enquiry

The Honeywell Sensepoint XCD transmitter is a zone one approved gas detector available in 3 versions; Flammable,  Toxic and Oxygen. Supplied complete with a stainless steel sensor cartridge, tested and calibrated, ready for immediate operation. Replacement sensor cartridges install at the base of the unit and automatically configure.

A tri-colour backlit LCD indicates the unit’s status at a glance, even from a distance. A steady green backlight indicates normal operation; flashing yellow indicates fault, and flashing red indicates an alarm. Configuration and operation are by non-intrusive magnetic switches.

XCD accepts catalytic bead or infrared flammable sensors, 0 to 100% LEL. Infra-red sensors detect Methane, Propane (with cross sensitivities to Ethylene and Butane) and Carbon Dioxide.

Electrochemical sensors are available for Oxygen and toxic gases; Carbon Monoxide, Hydrogen Sulphide, Nitrogen Dioxide & Hydrogen.

  • Approvals; ATEX, IECEx, UL, c-UL & INMETRO
  • Relays two programmable alarms & one programmable fault
  • Three-wire, 4-20mA output (sink or source adjustable)
  • RS485 Modbus interface for remote diagnostics & configuration (optional)
  • Remote sensor option (Toxic & O2)
  • Inhibited outputs prevent false alarms during maintenance
  • Suitable for use Indoor or Outdoor
  • Ingress Protection IP66
  • Stainless steel or aluminium housing
  • EC units use Honeywell Surecell sensors
  • Common transmitter interface provides uniformity, less training and maintenance stock
  • Warranty XCD unit 24 months, sensors 12 months
  • Weight: LM25 Aluminium Alloy models 2.0kg/4.4 lbs. 316 Stainless Steel versions 5.0kg/11lbs

Installation

  • Integral horizontal mounting plate included vertical or duct mounting options
  • Display module removable for access to terminals
  • Terminals unplug for ease of wiring

Sensepoint XCD includes a pre-fitted sensor, nylon weather protection, stainless steel blanking plug, magnetic wand, hex keys, printed quick start guide and CD-ROM.

Enquire About This Product

Title Size
Sensepoint XCD Brochure 2 MB
Sensepoint XCD_specsheet 249 KB
Engineering Specifications-Sensepoint XCD 207 KB
Sensepoint XCD Product Overview 712 KB
Sensepoint XCD Training Presentation 2 MB
Sensepoint XCD-Technical Manual 7 MB
Reflex_Tech Note 235 KB
SureCell TechNote 391 KB
BRO302_Industrial_Fixed_Brochure_FLR_41312N 1 MB
Gas Book Americas 5 MB
Petrochemical_Industry 538 KB
WasteWater_Indudtry 438 KB

Additional information

Weight 0.09 kg

Ordering Information

Instrument – ATEX/IECEx/CHINA Approval (316SS)

SPXCDASMFX ATEX/IECEx and AP approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry
SPXCDASMRX ATEX/IECEx and AP approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry
SPXCDASMPX ATEX/IECEx and AP approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry
SPXCDASMO1 ATEX/IECEx and AP approved SP XCD Oxygen 25.0%/Vol with 316SS, M20 Entry
SPXCDASMNX ATEX/IECEx and AP approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with 316SS, M20 Entry
SPXCDASMHX ATEX/IECEx and AP approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, M20 Entry
SPXCDASMCX ATEX/IECEx and AP approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, M20 Entry
SPXCDASMG1 ATEX/IECEx and AP approved SP XCD Hydrogen 0-1000ppm with 316SS, M20 Entry
SPXCDASMB1 ATEX/IECEx and AP approved SP XCD Carbon Dioxide IR 0-2.00%VOL with 316SS, M20 Entry

Instrument – ATEX/IECEx/CHINA Approval (LM25)

SPXCDALMFX ATEX/IECEx and AP approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry
SPXCDALMRX ATEX/IECEx and AP approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry
SPXCDALMPX ATEX/IECEx and AP approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry
SPXCDALMO1 ATEX/IECEx and AP approved SP XCD Oxygen 25.0%/Vol with LM25, M20 Entry
SPXCDALMNX ATEX/IECEx and AP approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with LM25, M20 Entry
SPXCDALMHX ATEX/IECEx and AP approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, M20 Entry
SPXCDALMCX ATEX/IECEx and AP approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with LM25, M20 Entry
SPXCDALMG1 ATEX/IECEx and AP approved SP XCD Hydrogen 0-1000ppm with LM25, M20 Entry
SPXCDALMB1 ATEX/IECEx and AP approved SP XCD Carbon Dioxide IR 0-2.00%VOL with LM25, M20 Entry

Instrument – UL/CSA Approval (316SS)

SPXCDUSNFX UL/CSA approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4″NPT Entry
SPXCDUSNRX UL/CSA approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4″NPT Entry
SPXCDUSNPX UL/CSA approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4″NPT Entry
SPXCDUSNO1 UL/CSA approved SP XCD Oxygen 25.0%/Vol with 316SS, 3/4″NPT Entry
SPXCDUSNHX UL/CSA approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, 3/4″NPT Entry
SPXCDUSNCX UL/CSA approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, 3/4″NPT Entry
SPXCDUSNNX UL/CSA approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with 316SS, 3/4″NPT Entry
SPXCDUSNG1 UL/CSA approved SP XCD Hydrogen 0-1000ppm with 316SS, 3/4″NPT Entry
SPXCDUSNB1 UL/CSA approved SP XCD Carbon Dioxide IR 0-2.00%VOL with 316SS, 3/4″NPT Entry

Instrument – UL/CSA Approval (LM25)

SPXCDULNFX UL/CSA approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4″NPT Entry
SPXCDULNRX UL/CSA approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4″NPT Entry
SPXCDULNPX UL/CSA approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4″NPT Entry
SPXCDULNO1 UL/CSA approved SP XCD Oxygen 25.0%/Vol with LM25, 3/4″NPT Entry
SPXCDULNHX UL/CSA approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, 3/4″NPT Entry
SPXCDULNCX UL/CSA approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with LM25, 3/4″NPT Entry
SPXCDULNNX UL/CSA approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with LM25, 3/4″NPT Entry
SPXCDULNG1 UL/CSA approved SP XCD Hydrogen 0-1000ppm with LM25, 3/4″NPT Entry
SPXCDULNB1 UL/CSA approved SP XCD Carbon Dioxide IR 0-2.00%VOL with LM25, 3/4″NPT Entry

Instrument – ATEX/IECEx/CHINA Approval (316SS) with ModBus

SPXCDASMFXM ATEX/IECEx and AP approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with ModBus
SPXCDASMRXM ATEX/IECEx and AP approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with ModBus
SPXCDASMPXM ATEX/IECEx and AP approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with ModBus
SPXCDASMO1M ATEX/IECEx and AP approved SP XCD Oxygen 25.0%/Vol with 316SS, M20 Entry, with ModBus
SPXCDASMNXM ATEX/IECEx and AP approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with 316SS, M20 Entry, with ModBus
SPXCDASMHXM ATEX/IECEx and AP approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, M20 Entry, with ModBus
SPXCDASMCXM ATEX/IECEx and AP approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, M20 Entry, with ModBus
SPXCDASMG1M ATEX/IECEx and AP approved SP XCD Hydrogen 0-1000ppm with 316SS, M20 Entry
SPXCDASMB1M ATEX/IECEx and AP approved SP XCD Carbon Dioxide IR 0-2.00%VOL with 316SS, M20 Entry, with ModBus

Instrument – ATEX/IECEx/CHINA Approval (LM25) with ModBus

SPXCDALMFXM ATEX/IECEx and AP approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry, with ModBus
SPXCDALMRXM ATEX/IECEx and AP approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry, with ModBus
SPXCDALMPXM ATEX/IECEx and AP approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry, with ModBus
SPXCDALMO1M ATEX/IECEx and AP approved SP XCD Oxygen 25.0%/Vol with LM25, M20 Entry, with ModBus
SPXCDALMNXM ATEX/IECEx and AP approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with LM25, M20 Entry, with ModBus
SPXCDALMHXM ATEX/IECEx and AP approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, M20 Entry, with ModBus
SPXCDALMCXM ATEX/IECEx and AP approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with LM25, M20 Entry, with ModBus
SPXCDALMG1M ATEX/IECEx and AP approved SP XCD Hydrogen 0-1000ppm with LM25, M20 Entry, with ModBus
SPXCDALMB1M ATEX/IECEx and AP approved SP XCD Carbon Dioxide IR 0-2.00%VOL with LM25, M20 Entry, with ModBus

Instrument – UL/CSA Approval (316SS) with ModBus

SPXCDUSNFXM UL/CSA approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4″NPT Entry, with ModBus
SPXCDUSNRXM UL/CSA approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4″NPT Entry, with ModBus
SPXCDUSNPXM UL/CSA approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4″NPT Entry, with ModBus
SPXCDUSNO1M UL/CSA approved SP XCD Oxygen 25.0%/Vol with 316SS, 3/4″NPT Entry, with ModBus
SPXCDUSNHXM UL/CSA approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, 3/4″NPT Entry, with ModBus
SPXCDUSNCXM UL/CSA approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, 3/4″NPT Entry, with ModBus
SPXCDUSNNXM UL/CSA approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with 316SS, 3/4″NPT Entry, with ModBus
SPXCDUSNG1M UL/CSA approved SP XCD Hydrogen 0-1000ppm with 316SS, 3/4″NPT Entry, with ModBus
SPXCDUSNB1M UL/CSA approved SP XCD Carbon Dioxide IR 0-2.00%VOL with 316SS, 3/4″NPT Entry, with ModBus

Instrument – UL/CSA Approval (LM25) with ModBus

SPXCDULNFXM UL/CSA approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4″NPT Entry, with ModBus
SPXCDULNRXM UL/CSA approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4″NPT Entry, with ModBus
SPXCDULNPXM UL/CSA approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4″NPT Entry, with ModBus
SPXCDULNO1M UL/CSA approved SP XCD Oxygen 25.0%/Vol with LM25, 3/4″NPT Entry, with ModBus
SPXCDULNHXM UL/CSA approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, 3/4″NPT Entry, with ModBus
SPXCDULNCXM UL/CSA approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with LM25, 3/4″NPT Entry, with ModBus
SPXCDULNNXM UL/CSA approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with LM25, 3/4″NPT Entry, with ModBus
SPXCDULNG1M UL/CSA approved SP XCD Hydrogen 0-1000ppm with LM25, 3/4″NPT Entry, with ModBus
SPXCDULNB1M UL/CSA approved SP XCD Carbon Dioxide IR 0-2.00%VOL with LM25, 3/4″NPT Entry with ModBus

Accessories

S3KCAL Calibration cup
SPXCDCC Collecting cone for use with lighter than air gases
SPXCDDMK Duct mounting kit
SPXCDMTBR Mounting bracket (inc. bolts, nuts, brackets)
SPXCDSDP Sunshade / Deluge Protection
00780-A-0100 Honeywell Junction Box- Bartec OTB122 With Continuity Plate 1 X 25mm – 3 X 20mm Entries – ATEX Approved

Sensepoint XCD Sensors (316 Stainless Steel)

SPXCDXSFXSS Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL)
SPXCDXSRXSS Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL)
SPXCDXSO1SS Oxygen 25.0%/Vol only
SPXCDXSHXSS Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm)
SPXCDXSCXSS Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm)
SPXCDXSNXSS Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm)
SPXCDXSG1SS Hydrogen 0-1000ppm only
SPXCDXSPXSS Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL)
SPXCDXSB1SS Carbon Dioxide IR 0-2.00%VOL only

Sensepoint XCD Transmitter (without Sensor)

SPXCDALMTXO ATEX/IECEx/China approved Sensepoint XCD O2 Transmitter, LM25 with M20 Entry
SPXCDALMTXT ATEX/IECEx/China approved Sensepoint XCD Toxic Transmitter, LM25 with M20 Entry
SPXCDALMTXF ATEX/IECEx/China approved Sensepoint XCD IR and FLAM Transmitter, LM25 with M20 Entry
SPXCDASMTXO ATEX/IECEx/China approved Sensepoint XCD O2 Transmitter, 316SS with M20 Entry
SPXCDASMTXT ATEX/IECEx/China approved Sensepoint XCD Toxic Transmitter, 316SS with M20 Entry
SPXCDASMTXF ATEX/IECEx/China approved Sensepoint XCD IR and FLAM Transmitter, 316SS with M20 Entry
SPXCDALMTXOM ATEX/IECEx/China approved Sensepoint XCD O2 Transmitter, LM25 with M20 Entry and ModBus
SPXCDALMTXTM ATEX/IECEx/China approved Sensepoint XCD Toxic Transmitter with LM25, M20 Entry, with ModBus
SPXCDALMTXFM ATEX/IECEx/China approved Sensepoint XCD IR and FLAM Transmitter, LM25 with M20 Entry and ModBus
SPXCDASMTXOM ATEX/IECEx/China approved Sensepoint XCD O2 Transmitter, 316SS with M20 Entry and ModBus
SPXCDASMTXTM ATEX/IECEx/China approved Sensepoint XCD Toxic Transmitter, 316SS with M20 Entry and ModBus
SPXCDASMTXFM ATEX/IECEx/China approved Sensepoint XCD IR and FLAM Transmitter, 316SS with M20 Entry and ModBus
SPXCDULNTXO UL approved Sensepoint XCD O2 Transmitter, LM25 with 3/4″NPT Entry
SPXCDULNTXT UL approved Sensepoint XCD Toxic Transmitter, LM25 with 3/4″NPT Entry
SPXCDULNTXF UL approved Sensepoint XCD IR and FLAM Transmitter, LM25 with 3/4″NPT Entry
SPXCDUSNTXO UL approved Sensepoint XCD O2 Transmitter, 316SS with 3/4″NPT Entry
SPXCDUSNTXT UL approved Sensepoint XCD Toxic Transmitter with 316SS, 3/4″NPT Entry
SPXCDUSNTXF UL approved Sensepoint XCD IR and FLAM Transmitter, 316SS with 3/4″NPT Entry
SPXCDULNTXOM UL approved Sensepoint XCD O2 Transmitter, LM25 with 3/4″NPT Entry and ModBus
SPXCDULNTXTM UL approved Sensepoint XCD Toxic Transmitter, LM25 with 3/4″NPT Entry and ModBus
SPXCDULNTXFM UL approved Sensepoint XCD IR and FLAM Transmitter, LM25 with 3/4″NPT Entry and ModBus
SPXCDUSNTXOM UL approved Sensepoint XCD O2 Transmitter, 316SS with 3/4″NPT Entry and ModBus
SPXCDUSNTXTM UL approved Sensepoint XCD Toxic Transmitter, 316SS with 3/4″NPT Entry and ModBus
SPXCDUSNTXFM UL approved Sensepoint XCD IR and FLAM Transmitter, 316SS with 3/4″NPT Entry and ModBus

Miscellaneous Spares

SPXCDDMF Replacement display module for Cat and IR
SPXCDDMT Replacement display module for O2 and Toxic
SPXCDDMFM Replacement display module (Cat and IR) with ModBus
SPXCDDMTM Replacement display module O2 and Toxic with ModBus
SPXCDTMF Replacement terminal module for Cat and IR
SPXCDTMO Replacement terminal module for O2
SPXCDTMT Replacement terminal module for Toxic
SPXCDMAG Magnet
SPXCDWP XCD Weatherproof cap
SPXCDSRLS Sensor Retainer with locking screw
SPXCDAKS Allen key for stopper
SPXCDHWES Hex wrench for earth screw
SPXCDEBS Earth Bracket and screws

In the past order descriptions referenced Zareba Sensepoint XCD or Sieger brand.

Enquire About This Product